Ottar Moller wrote:

Hi there,
I was adding a new CHP to a device and reused an old CHP.  I can't get the
new CHP working and when I list the CHP (d m=chp(B8)) I get:

CHPID B8:  TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE

When looking at the other CHPs for the same device I get:

CHPID B0:  TYPE=03, DESC=ESCON POINT TO POINT, ONLINE

They are both defined as CNC and I can't find out where to change TYPE=04 to
TYPE=03.

Any hints?

My hint:
The chpid is not connected,
...
...
or it is connected using broken cable,
or it is connected to un-enabled port in CU.


I'd suggest logon on SE (Support Element) and use diagnostics - Icon Channel Problem Determination, then Analyze Channel Information radiobutton.
Then check what's on the other end of ESCON.

--
Radoslaw Skorupka
Lodz, Poland

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html