Ottar Moller wrote:
Hi there,
I was adding a new CHP to a device and reused an old CHP. I can't get the
new CHP working and when I list the CHP (d m=chp(B8)) I get:
CHPID B8: TYPE=04, DESC=ESCON SWITCHED OR POINT TO POINT, ONLINE
When looking at the other CHPs for the same device I get:
CHPID B0: TYPE=03, DESC=ESCON POINT TO POINT, ONLINE
They are both defined as CNC and I can't find out where to change TYPE=04 to
TYPE=03.
Any hints?
My hint:
The chpid is not connected,
...
...
or it is connected using broken cable,
or it is connected to un-enabled port in CU.
I'd suggest logon on SE (Support Element) and use diagnostics - Icon
Channel Problem Determination, then Analyze Channel Information radiobutton.
Then check what's on the other end of ESCON.
--