Natasa,
Are the datasets with this MC becoming eligible for deletion? Check the
HSM output to see if you are getting non zero rc's suggesting that the
dataset will not be deleted because there is no HSM backup. If so there
is an HSM zap to override this, as mentioned on a mail recently from
Hermann Faber:
PATCH .MCVT.+431 BITS(......1.) /* Override the requirement */
/* that SMS-managed data sets */
/* have a backup copy before */
/* they can be expired */
Richard Marchant
Shoden Data Systems
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Natasa Savinc
Sent: 09 June 2005 11:40 AM
To: [email protected]
Subject: Expiring data sets
Hello,
I am tring to set up a management class for data sets that should expire
after 7 days. I don't wan't to back up the data.
The MC looks like this:
Expiration Attributes
Expire after Days Non-usage . : 7
Expire after Date/Days . . . . : 7
Retention Limit . . . . . . . : 7
Migration Attributes
Primary Days Non-usage . :
Level 1 Days Date/Days . :
Command or Auto Migrate . : NONE
Backup Attributes
Backup frequency . . . . . . . . . . . :
Number of backup versions . . . . . . . :
(Data Set Exists)
Number of backup versions . . . . . . . :
(Data Set Deleted)
Retain days only backup version . . . . :
(Data Set Deleted)
Retain days extra backup versions . . . :
Admin or User Command Backup . . . . . : NONE
Auto Backup . . . . . . . . . . . . . . : NO
Backup copy technique . . . . . . . . . : STANDARD
Nothing else is specified.
Storage group has following attributes:
Auto Migrate . . P (Y, N, I or P)
Auto Backup . . N (Y or N)
Auto Dump . . . N (Y or N)
Overflow . . . . N (Y or N)
However, data sets do not get deleted. What am I missing?
Regards,
Natasa
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html