I have always made do with the ISMF ACS test facility and a bevy of test
cases. 
I think Naviquest will let you do this in batch though I never set it up as
the on-line ISPF tools were sufficient for my needs.

If you have the luxury a separate test Sysplex and SMSPlex of course.

Vendor product?  DTS Software has what sounds like a useful test and
debugging tool SMS/Debug you might want to look at.

http://www.dtssoftware.com/product_sms.htm

Might make debugging safer, faster, more productive in a single image.

        Best Regards,

                Sam Knutson, GEICO
                Performance and Availability Management
                mailto:[EMAIL PROTECTED]
                (office)  301.986.3574

"Think big, act bold, start simple, grow fast..."


-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf
Of Neil Duffee
Sent: Monday, July 18, 2005 2:33 PM
To: [email protected]
Subject: [SMS] testing new SCDS configuration

Haven't seen any results so I thought I'd give it another go.  Anyone
willing to pat me on the back and say, "Go for it, sonny," or shake a mighty
finger with, "You *stoopid* fool!  Don't you know that..."  
*grin*

I'm/we're trying to move to a more sophisticated SMS setup from the basic
StorClas->StorGrp we have now and this's the first leap.  How do *you* test
a new SMS configuration before the production LPar?  
Again, tks for any help or suggestions...
----->  previous message  <-----
Date:         Thu, 30 Jun 2005 15:16:35 -0400
From:         Neil Duffee <[log in to unmask]>

Looking for opinions/affirmations on my line of thinking for testing a new
SCDS configuration. We're z/OS v1.4, z890, & MonoPlex'd but all the LPar's
are in a single SMSPlex ie. sharing COMMDS & ACDS. I've got a major change
in both SCDS & ACS which I've hand & batch
(NaviQuest) checked over & again but would love to try a live test. 

>From the single hint in the Storage Admin Ref, "If the COMMDS and ACDS are
different from the ones used by the remainder of the SMS complex, then the
system runs as a separate SMS complex." then I should be able to, in one
fell swoop, issue: SETSMS COMMDS(new)
ACDS(new) SCDS(new) 
        - 'cept that COMMDS is exclusive of other all other parms. 

So I'm thinkin' that, in the testing LPar, I need to: 

1 allocate new, empty COMMDS & ACDS
2 SETSMS SAVEACDS(new)
3 create SYS1.PARMLIB(IGDSMSnew) listing both the new ACDS & COMMDS
4 SET SMS=new 
        - starts a 'new' SMSplex containing only this 'test' LPar
5 SETSMS SCDS(new) 
        - activates the new configuration in the 'new' ACDS 
        - should *not* affect any other LPar (different SMSplex)
6 test the snot out of it before trying it on production 

My biggest worry is that the other LPars might pick up the configuration
change; production 'specially. Tks for all hints, warnings, and suggestions.

---------->  signature = 6 lines follows <--------------
Neil Duffee, Joe SysProg, U d'Ottawa, Ottawa, Ont, Canada
telephone:1 613 562 5800 x4585                 fax:1 613 562 5161
mailto:NDuffee of uOttawa.ca     http:/ /aix1.uottawa.ca/ ~nduffee
"How *do* you plan for something like that?" Guardian Bob, Reboot "For every
action, there is an equal and opposite criticism."
"Systems Programming: Guilty, until proven innocent" John Norgauer
2004

<>
==================== 
This email/fax message is for the sole use of the intended recipient(s) and
may contain confidential and privileged information.  Any unauthorized
review, use, disclosure or distribution of this email/fax is prohibited.  If
you are not the intended recipient, please destroy all paper and electronic
copies of the original message. 

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to