have planned 
IPL's over something this silly. Has anyone found a way around it or do 
you all just plan an IPL on some scheduled basis and call it a day?
...

Unfortunately, that's the only answer (I even got that from second level 
support).

I have never liked it and it started to become an issue when IBM released XMS 
through PCAUTH.

The flaw is that they never created a way to turn off the bit, so any ASID that 
is the target is non-reusable once the job terminates.

The only answer(s):

1. Make them big numbers.
2. Don't recycle all the jobs all the time.
3. IPL (too) often.

We can make it to just about 6 weeks.

-teD

In God we Trust!
All others bring data!
  -- W. Edwards Deming

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to