7F, not 80...
Robert Pelletier wrote:
I have been asked to define more 3390-3 devices to our system. Here is a piece
of an HCD report
PROCESSOR ID CSLF9672 TYPE 9672 MODEL RA4 CONFIGURATION MODE: LPAR T
---- SWITCH ----
ID PR CU DYN --- CONTROL UNIT --- CU-
CHPID TYPE MNGD SIDE MODE PN PN ID NUMBER TYPE-MODEL ADD
_____ ______ _____ ____ ____ ____________ ___ _____________________ ___
60 CNC SHR 0700 3990
______________________________________________________________________________
61 CNC SHR 070E 3990
______________________________________________________________________________
TOKEN: CSLF9672 01-03-16 11:49:03 TECH IODF03
UNIT ADDR UNIT
- RANGE -- DEVICE -- ADDR DEVICE
D PROTOCOL FROM TO NUMBER,RANGE START TYPE-MODE
_ ________ _________ ____________ _____ _________
00 4F 0900,80 00 3390 <<<<<<<<<<<Make this 00 80 0900,128?
______________________________________________________
00 4F 0900,80 00 3390 <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<
Can I simply get into HCD and wherever there is a 4F make it an 80 and wherever
there is an 80 for 3990/3390 devices make it 128?
Thanks in advance to all.
Bob Pelletier
Connecticut Student Loan Foundation
Rocky Hill, Connecticut
----------------------------------------------------------------------