This past weekend IBM applied LM code 530.11 with FP 11B to correct the 
situation where the SMF94VEC value is zero and the GUI interface for the 
VTS when looking at the active data screen shows no free cartridge scratch 
space available.

----- Forwarded by Patrick Falcone/US/Combined on 08/02/2005 11:12 AM 
-----


Patrick Falcone
04/28/2005 10:59 AM

        To:     IBM Mainframe Discussion List <[email protected]>
        cc: 
        Subject:        Re: VTS SMF 94 vec value zero after LM code 530.08 
applied

Yea, good point. I just went in there and pulled up the active data 
screen. The value is missing from the GUI as well. Thanks.





Robin Murray <[EMAIL PROTECTED]>
Sent by: IBM Mainframe Discussion List <[email protected]>
04/28/2005 12:36 PM
Please respond to IBM Mainframe Discussion List
 
        To:     [email protected]
        cc: 
        Subject:        Re: VTS SMF 94 vec value zero after LM code 530.08 
applied


quite a coincidence eh? 

do you have the library web service enabled? if so, you might want to 
check out the active data page and see if the free storage numbers are 
correct. if it's also 0 that may help ibm to nail the problem.

Robin Murray
Tel: (902) 453-7300 x4177
Cell: (902) 430-0637

[EMAIL PROTECTED]
Sent by: IBM Mainframe Discussion List <[email protected]>
04/28/2005 11:17 AM
Please respond to IBM Mainframe Discussion List
 
        To:     [email protected]
        cc: 
        Subject:        Re: VTS SMF 94 vec value zero after LM code 530.08 

applied


Thanks Robin. The library id is correct. This is code that has been 
working for quite a while. I tracked down the date where the vec value 
zeroed. It coincided with the date that the LM code had been applied.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to