Today I coded this: ICM R1,B'1111',(R14) When I meant this: ICM R1,B'1111',0(R14)
I see that FLAG(PAGE0) found the unintended instruction right away. It took me a few minutes to go over the new code to find out why it wasn't working as expected. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html