> -----Original Message-----
> From: IBM Mainframe Discussion List On Behalf Of Barry Schwarz
> 
> Unless the catalog has a PDSE indicator and you use the same 
> catalog for both IPL's, how would anyone know of this "inconsistency"?

The same master catalog is used for both SYSRES sets.  I don't know whether
there is or is not such a thing as a "PDSE indicator" for a non-SMS dataset.
One certainly is not coded in the IDCAMS command to indirectly catalog a
dataset (DEFINE NONVSAM NAME(data.set.name) DEVICETYPES(0000)
VOLUMES(&SYSRn)).