As I posted recently, in order to install the $ADD/REP exit code, you have
to do one (last!) warm start with all parameters defined for the exit point
and the load module. JES2 will not incorporate newly defined exit points or
load modules on a hot start.

Once the $ADD/REP code is implemented via warm start, you can add or change
any exit code--including $ADD/REP itself--via command.

.
.
.
JO.Skip Robinson
Southern California Edison Company
SHARE MVS Program Co-Manager
626-302-7535 Office
323-715-0595 Mobile
[EMAIL PROTECTED]

IBM Mainframe Discussion List <[email protected]> wrote on 09/19/2005
08:45:41 AM:

> Ah crud, that didn't work.  Anyone have any other ideas?
>
> At 10:26 AM 9/19/2005, Adam Floro wrote:
>
> >Oh...I think I may have solved it:  I forgot a LOADMOD(EXIT5) statement
in
> >jes parm.
> >
> >Adam
> >
> >At 10:11 AM 9/19/2005, Adam Floro wrote:
> >>Hi, all.  I downloaded CBT JES2 File #140 Bob Break's
$REPEXIT/$ADDEXIT,
> >>successfully assemble/link-edited it in my test system, bounced test,
and
> >>tried it out with the following command:
> >>
> >>    $REPEXIT,EXIT3
> >>
> >>This command gives the following error:
> >>
> >>    $HASP650 EPEXIT,EXI INVALID OPERAND OR MISPLACED OPERAND
> >>
> >>It's as if the $R command is being processed and not the $REPEXIT
command.
> >>
> >>Anyone have any suggestions/ideas?
> >>
> >>Adam

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to