Carlos A Bodra wrote:
Hi,

Can anyone tell me about performance of 2 x 2105-F20 with PPRC (v1 or v2)
using 2 or 4 escon cables between them?

At my mind I have that 4 is better than 2, alternate physical path etc...,
but any real expirience. Or there are a Redbook about?

There are quite many redbooks about copy services and PPRC - just use search engine.

Regarding to your question:
I'd vote for 4 or even more ESCONs.
Everything depends on your I/O activity and host-to-ESS connectivity.
As a general rule - channels for PPRC shouldn't make bottleneck.
Things are changing when you use non-synchronous copy (PPRC-XD, XRC, etc.)

--
Radoslaw Skorupka
Lodz, Poland

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to