Paul Gilmartin wrote:
On Mon, 10 Aug 2009 17:48:31 -0500, Richard Peurifoy wrote:
Paul Gilmartin wrote:
On Mon, 10 Aug 2009 16:52:59 -0500, Patrick O'Keefe wrote:
I'm just puzzled that the enhancement limited itself to QSAM.
No mention of BPAM.
I had hoped this was an oversight in the doc, but apparently
not. An assembly with:
//SYSLIB DD UNIT=SYSALLDA,SPACE=(80,(1,1)),
// RECFM=FB,LRECL=80,BLKSIZE=80
// DD DISP=SHR,DSN=SYS1.MACLIB
Unless there is a typo, you concatenated a seq file (no directories)
with the PDS.
You mean I need _two_ commas, not just one?
Why does OPEN let me do that, and not just ABEND?
OK. I changed to:
6 //SYSLIB DD UNIT=SYSALLDA,SPACE=(80,(1,,1)),
// DISP=NEW,DSN=&&MAC,
// RECFM=FB,LRECL=80,BLKSIZE=80
X/SYSLIB DD DSN=SYS1.MACLIB,DISP=SHR
7 // DD DISP=SHR,DSN=SYS1.MACLIB
I needed to specify DISP and DSN to override those in the
library proc.
And it fails the same with:
********************************* TOP OF DATA **********************************
** ASMA999U Assembly terminated - SYNAD Exit taken - Permanent I/O error on SYSL
,HELLO ,C ,4140,D,SYSLIB ,UNKOWN,WRNG.LEN.RECORD,00001F7100030
******************************** BOTTOM OF DATA ********************************
Experimental control: if I change BLKSIZE from 80 to 32760,
it assembles with no errors, and library macros are fetched
from the second catenand.
Interesting, I tried a temp PDS, and also failed, so I tried
a permanent PDS with a small blksize and it worked ok.
I then tried allocating a temp pds in a previous step and passed it.
This also worked ok. I don't know why it fails if allocated in
the same step.
--
Richard
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO