On Mon, 14 Sep 2009 13:21:24 -0700, Mark Yuhas <mark.yu...@paccar.com> wrote:

>We have 3 LPARs in our sysplex all in the same MAS.  All running z/OS
>1.7.  We have an anomaly we can't explain.
>When a job is submitted on System A, it is converted on system B.  Due
>to the scheduling environment, the job
>executes and ABENDs on System A.  Designating SYSAFF=A resolved the
>problem.
>   
>Even though both systems have the same PROC name.  The PROCs our
>different on each system.  My conclusion,
>albeit uninformed, is that when the job was submitted on system A, all
>of the Conversion PCEs on System A were
>active and so a Conversion PCE on system B performed the conversion.
>
>Is there a way, besides an exit, to force a job without a SYSAFF
>designation to be converted on the same system
>that it was submitted on?  
>

You can update the INTRDR statement in the init deck or via operator
command.  If you share the init deck, you can use &SYSNAME.

Mark
--
Mark Zelden
Sr. Software and Systems Architect - z/OS Team Lead
Zurich North America / Farmers Insurance Group - ZFUS G-ITO
mailto:mark.zel...@zurichna.com
z/OS Systems Programming expert at http://expertanswercenter.techtarget.com/
Mark's MVS Utilities: http://home.flash.net/~mzelden/mvsutil.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html