On Thu, 2009-11-26 at 09:13 -0600, Kirk Wolf wrote:
> SMOP:
> 
> int len = rdwInputStream.read(recbuf, 4);
> int rdw = (len+4)<<16;
> ByteUtil.putInt(rdw, recbuf, 0);
> 

Yes, that will do it. I posted another error/problem on the JZOS forum.
My SMF data on the PC is VBS and is still segmented. FTP transfers it as
segmented and does not coalesce the multiple segments into a single
logical record. Also RDWInputRecordStream returns each segment
independently with no indication that the logical record is part of a
segmented series of records. IOW, it cannot be successfully used to
process VBS records on the PC. So much for using it for my SMF
processing, unless I preprocess the SMF data from VBS to a VB dataset
first and download the VB dataset. I don't know if Co:Z's tranfer with
the RDW option coalesces the segments of a segment record into a single
VB record or not.

This was with JZOS 2.3.2 from Alphaworks.
 
-- 
John McKown
Maranatha! <><

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to