On Mon, Nov 30, 2009 at 7:28 PM, Stock, Roger W <[email protected]> wrote:

> Hi all,
>
> A vendor supplied me with a very large single job to install their
> software (10,000+ lines).
>
> The jobs abends the JES2 converter:
>  IEC031I D37-04,IFG0554P,JES2,JES2,SYS00009,VIO ,
> ,SYS09328.T110458.RA000.JES2.R0400331
>  IEF196I IEC031I D37-04,IFG0554P,JES2,JES2,SYS00009,VIO ,      ,
>
>  IEF196I SYS09328.T110458.RA000.JES2.R0400331
>
>  IEFC683I CONVERTER TERMINATED DUE TO SD37 ABEND REASON=00000004
>
>
> How do I adjust JES2 to handle this job?
> We are on zOS 1.9.
>
> Roger
>
> Can't see if this has been suggested but have you tried to issue the SUBmit
command from the member list screen of edit ie to the left of the member
name.  We used to have these sort of problems with very large IMS sysgens
and that is how I was able to submit them.

Jim McAlpine

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to