> -----Original Message-----
> From: IBM Mainframe Discussion List 
> [mailto:[email protected]] On Behalf Of Gibney, Dave
> Sent: Tuesday, February 02, 2010 12:51 PM
> To: [email protected]
> Subject: Re: ACS routines and OMVS
> 
> I'm on z/OS 1.9 with maintenance to RSU0911
> 
> Dave Gibney

Well, I did a quick test on my z/OS 1.10 sandbox. All I did was change the 
MGMTCLAS ACS routine to assign a different management class to any TSSPV 
dataset with an LLQ of ZFS. Before the change, I got the old management class. 
After the change, I got the new management class. So it does work as expected 
on z/OS 1.10.

Would you be open to another slight change? In your mapping file, change the 
"allocuser" to "allocany" and see what happens?

--
John McKown 