>I was just thinking - I wonder if the blocksize I used is bad for PDS/E, givin 
>the 4096 page six.

The 'logical' blocksize really doesn't matter.
All data is stored in 'physical' blocks of 4096, regardless of the blocksize 
specified.


>Will it write blocks at 7520, or just write 4K blocks?  >Should I make the 
>blocksize something with a closer multiple of 4096?

Don't bother.
The problem is akin to cluster sizes on PC's.
There is a minimum of 4K per member, regardless of the other attributes.

-
Too busy driving to stop for gas!

----------------------------------------------------------------------