One observed the following event:
Hard disk failed in a dasd box (EMC DMX3). Obviously no data was lost, because it was part of RAID group, so the array took spare disk and rebuilt the RAID group. The array is connected to another one using SRDF/S. During the rebuild process some invalid tracks appeared (SQ command showed it). That means some of data was not sent to secondary array. That means that during RAID rebuild data are not synchronously replicated!

Q1: Is it normal behavior?

Q2: What about other vendors? Does IBM or HDS (or STK/Sun/Oracle) freeze remote replication process during the time of RAID reconstruction process? Does HDD failure affect process of (synchronous) TrueCopy or PPRC ?

--