1- Check for Differences between sysplex PI and local PI values. If there is 
too much difference then you may need to make them separate. The reason for 
this is WLM checks sysplex PI values first.
2- If you are using IRD again for better IRD decisions you may need to separate 
them.
I personally prefer 1 min or 20 sec interval data to check these values but it 
can be seen from smf rmf records too I guess. I used this method and we got a 
significant improvement on service class PI values after we have done the 
seperation and also in IRD decisions . But as Peter mentioned too `it depends ` 
on platform . So I recommend to read that nice article as well.
Regards
Meral



-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of 
gsg
Sent: Saturday, April 17, 2010 2:53 AM
To: [email protected]
Subject: [IBM-MAIN] WLM Service Class question

We have two production LPARs and two test LPARs.  We have different 
service classes for Production batch and Test batch.  My question is should 
both production LPARs use the same service class or should we have different 
service classes for each production LPAR as well.  Not sure if it would matter 
or not, but each production LPAR is for a different bank we support.

TIA

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html


This message and attachments are confidential and intended solely for the 
individual(s) stated in this message. If you received this message although you 
are not the addressee, you are responsible to keep the message confidential. 
The sender has no responsibility for the accuracy or correctness of the 
information in the message and its attachments. Our company shall have no 
liability for any changes or late receiving, loss of integrity and 
confidentiality, viruses and any damages caused in anyway to your computer 
system.  

Bu mesaj ve ekleri, mesajda gonderildigi belirtilen kisi/kisilere ozeldir ve 
gizlidir. Bu mesajin muhatabi olmamaniza ragmen tarafiniza ulasmis olmasi 
halinde mesaj iceriginin gizliligi ve bu gizlilik yukumlulugune uyulmasi 
zorunlulugu tarafiniz icin de soz konusudur. Mesaj ve eklerinde yer alan 
bilgilerin dogrulugu ve guncelligi konusunda gonderenin ya da sirketimizin 
herhangi bir sorumlulugu bulunmamaktadir. Sirketimiz mesajin ve bilgilerinin 
size degisiklige ugrayarak veya gec ulasmasindan, butunlugunun ve gizliliginin 
korunamamasindan, virus icermesinden ve bilgisayar sisteminize verebilecegi 
herhangi bir zarardan sorumlu tutulamaz.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to