1- Check for Differences between sysplex PI and local PI values. If there is too much difference then you may need to make them separate. The reason for this is WLM checks sysplex PI values first. 2- If you are using IRD again for better IRD decisions you may need to separate them. I personally prefer 1 min or 20 sec interval data to check these values but it can be seen from smf rmf records too I guess. I used this method and we got a significant improvement on service class PI values after we have done the seperation and also in IRD decisions . But as Peter mentioned too `it depends ` on platform . So I recommend to read that nice article as well. Regards Meral
-----Original Message----- From: IBM Mainframe Discussion List [mailto:[email protected]] On Behalf Of gsg Sent: Saturday, April 17, 2010 2:53 AM To: [email protected] Subject: [IBM-MAIN] WLM Service Class question We have two production LPARs and two test LPARs. We have different service classes for Production batch and Test batch. My question is should both production LPARs use the same service class or should we have different service classes for each production LPAR as well. Not sure if it would matter or not, but each production LPAR is for a different bank we support. TIA ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html This message and attachments are confidential and intended solely for the individual(s) stated in this message. If you received this message although you are not the addressee, you are responsible to keep the message confidential. The sender has no responsibility for the accuracy or correctness of the information in the message and its attachments. Our company shall have no liability for any changes or late receiving, loss of integrity and confidentiality, viruses and any damages caused in anyway to your computer system. Bu mesaj ve ekleri, mesajda gonderildigi belirtilen kisi/kisilere ozeldir ve gizlidir. Bu mesajin muhatabi olmamaniza ragmen tarafiniza ulasmis olmasi halinde mesaj iceriginin gizliligi ve bu gizlilik yukumlulugune uyulmasi zorunlulugu tarafiniz icin de soz konusudur. Mesaj ve eklerinde yer alan bilgilerin dogrulugu ve guncelligi konusunda gonderenin ya da sirketimizin herhangi bir sorumlulugu bulunmamaktadir. Sirketimiz mesajin ve bilgilerinin size degisiklige ugrayarak veya gec ulasmasindan, butunlugunun ve gizliliginin korunamamasindan, virus icermesinden ve bilgisayar sisteminize verebilecegi herhangi bir zarardan sorumlu tutulamaz. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html