we have a z01-BC model K03, 4 LPARs, equipped with 4 OSA E Hello list, we have a z01-BC model K03, 4 LPARs, equipped with 4 OSA Express-3 1GB Ethernet SX (CHPID OSD) and 2 OSA Express-2 (CHPID OSC).
Last Sunday we had to swap our network switch with a new one, and after we connected the cables coming from all OSAs to the new switch, we were able to ping/telnet to the OSCs (I had back MCS consoles and TSO via non-SNA) but we weren't be able to ping/telnet to the OSDs anymore. Issuing D TCPIP,,N,DEV from the console showed all 4 devices in ACTIVE status. Issuing a TSO ping from one LPAR to all others was successful, too. D NET,TRL,TRLE=trle_name for our TRLEs showed ACTIVE as well. Eventually we had to shutdown all 4 LPARs, configuring all 4 OSAs OSD off from the Service Element, put the same cards in Service Mode, put everything back on line, IPL and voila', the OSAs OSD were reachable again. I can't believe that a sophisticated hw like the z10 and its OSA-Express cards need such a reset action after a switch has been swapped. My impression is that we missed a much easier solution which could have prevented us to shutdown an entire Sysplex and be cut off from the rest ofthe world for two hours. Can someone shed some light ? Walter Marguccio z/OS Systems Programmer BELENUS LOB Informatic GmbH Munich - Germany ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html