On Thu, 27 Oct 2005 14:45:26 -0500, McKown, John
<[EMAIL PROTECTED]> wrote:

>> -----Original Message-----
>> From: IBM Mainframe Discussion List
>> [mailto:[EMAIL PROTECTED] On Behalf Of DeFabritus, Peter
>> [NCSUS Non-J&J]
>> Sent: Thursday, October 27, 2005 2:41 PM
>> To: [email protected]
>> Subject: Re: DFSMSdfp ACS routine question.
>>
>
><snip>
>
>>
>> The trick I have used in the past is to assign a different
>> sysplex name in
>> the LOADxx parameter tailored for DR, then reference the
>> &SYSPLEX variable
>> in the ACS routines to control the logic path.
>>
>
>Wouldn't that mess up my couple datasets? Or do rebuild them at DR? We
>just use our dumped ones.
>
>--
>John McKown
>Senior Systems Programmer
>UICI Insurance Center
>Information Technology
>
>This message (including any attachments) contains confidential
>information intended for a specific individual and purpose, and its'
>content is protected by law.  If you are not the intended recipient, you
>should delete this message and are hereby notified that any disclosure,
>copying, or distribution of this transmission, or taking any action
>based on it, is strictly prohibited.
>
>
>----------------------------------------------------------------------
>For IBM-MAIN subscribe / signoff / archive access instructions,
>send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
>Search the archives at http://bama.ua.edu/archives/ibm-main.html


We had a separate set of preformatted couple data sets for DR, and the DR
LOADxx member caused a special COUPLExx pointing to these data sets to be
used, so that nothing needed to be done at the DR site.

----------------------------------------------------------------------