Lizette,

  The following is valid for Zos 1.9

 /*  ALLOW RECALL TO ACCESS TAPES ASSIGNED TO RECYCLE OR TAPECOPY     
 /********************************************************************
  PATCH .MCVT.+315 X'05'                                              
  PATCH .MCVT.+53 BITS(.....1..)                                      

Thank You,
Dave O'Brien
NIH Contractor
________________________________________
From: Lizette Koehler [[email protected]]
Sent: Tuesday, June 15, 2010 11:14 AM
To: [email protected]
Subject: How to terminate a RECYCLE on DFHSM

I started a recycle and now need to stop it.  I issue the F DFHSM,HOLD RECYCLE 
but a display says HELD ACTIVE.

When will it go inactive?  At the end of the task/volume/??

Does RECYCLE hold up my RECALL tasks on DFHSM.

Lizette

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to