The DROP command is a TCPIP command, not a TELNET command. 
VARY TCPIP,[tcpip_stack_name],DROP,CONN=007EEE8E

Mike Stayton
z/OS Communications Server
[email protected]


> 
> Please respond to IBM Mainframe Discussion List
> 
> All list,
> 
> I am issuing the command VARY TCPIP, TN3270U, CMD = DROP, CONNECTION = 
> 007EEE8E to drop a connection, the result is
> 
> EZZ6048I VARY TELNET COMMAND FAILED WITH RCODE 803E
> EZZ6035I TELNET DEBUG PROFILE WARNING, LINE: N * / * The MOD: EZBTMCMD 
225
> RCODE: 803E-00 Parameter on command is invalid.
>   Parm1:         Parm2:         PARM3: CMD = DROP
> 
> I have used the abbreviated parameters and the error is the same. What 
> I'm doing wrong.
> Drop = Dr , Connection= Conn, Vary= V
> 
> 
> 
> Can anyone help me? tell me why the drop parameter is not being 
accepted.
> 
> Thank you
> 
> -- 
> Hélio José da Silva
> Depto. Software Básico
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to