Hi all,

Has anyone implemented System Managed Coupling Facility Structure Duplexing
?

I am looking for real RMF Coupling Facility reports with System Managed
Duplexing data (of course I need only reports without company name and etc
data - only technical reports). Reports from my site in return if someone
needs.

I try to understand the relationship between:
- peer subchannel wait contention (PR WT) time,
- waiting-for-peer-completion contention (PR CMP) time,
- CF-to-CF  service time,
and altogether service time for system managed duplexing structure.
So real RMF CF reports would be very useful.

Thanks in advance.
Witek
[EMAIL PROTECTED]

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to