I have contacted Marco off-line with advice about his migration.

For others that might be in a similar situation, migrating to rmm, it is
best not to use the UTC(YES) option during parallel running. Rather wait
until in production and then consider implementation.

Our conversion tools generate the EDGUTIL SYSIN statement:
CONTROL CDSID(SYS1) EXTENDEDBIN(YES) STACKEDVOLUME(YES)
this has neither UTC not CATSYNCH.  It is best to use the one we generate.
Running CATSYNCH is best best way to ensure that rmm and catalog status info
is in synch.

When you switch to and from DST rmm always uses the current systems time
zone offset to calculate the local time values to be displayed. Consequently
there would be 1 hour time difference shown for a display performed when DST
is used and after switch from DST.

Mike Wood    RMM Development

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to