So how do you allow DBAs and CICS SAs work on ICAT at the same time or is
this something they should not be doing anyway?  Something that should be
centrally managed?

On Sat, Nov 20, 2010 at 2:32 AM, Stephen Hall <[email protected]>wrote:

>
> _______________________________________________________________________________________
>
> Note: This e-mail is subject to the disclaimer contained at the bottom of
> this message.
>
> _______________________________________________________________________________________
>
>
> >Date:    Fri, 19 Nov 2010 08:59:39 +0100
> >From:    "Vernooij, CP - SPLXM" <[email protected]>
> >Subject: Re: How Many OMEGAMON ICATs Can Run At The Same Time?.
> >
> >"George Henke" <[email protected]> wrote in message
> >news:<[email protected]>...
> >> Is anyone able to run more than one ICAT (formerly CICAT) at the same
> >>time,
> >> eg ICAT for CICS, ICAT for DB2, etc.
> >>
> >> --
> > George Henke
> >
> >You mean: several users configuring Omegamon components simultaneously?
> >I think they will collide regularly, because they are configuring the same
> RTE.
> >The only way should be to separate them right from the beginning to their
> own RTEs and datasets.
> >
> >Kees.
>
> Yes, that would be the only way to do it, but not what I would recommend,
> as it would lead to a lot of duplication,
> as well as increased overhead in applying maintenance etc.
>
> My suggestion would be to nominate an ICAT / Omegamon Installation owner
> who manages the installation and
> configuration on behalf of all teams. Depending on the number of LPARS /
> RTES you have I would also recommend
> looking at the batch ICAT Process, or even the new PARMLIB installation
> process. I have 9 LPARS configured
> with most Omegamon components and use the batch process, I can regenerate a
> new RTE in about 30 minutes depending
> on the number of DB2 and IMS regions in the RTE.
>
>
> Thanks & Regards,
> –––––––––––––––––––––––––––––––––––––––––––––
> Stephen Hall
> Mainframe Platform Manager
> INSURANCE AUSTRALIA GROUP (IAG)
>
> _______________________________________________________________________________________
>
> The information transmitted in this message and its attachments (if any) is
> intended
> only for the person or entity to which it is addressed.
> The message may contain confidential and/or privileged material. Any
> review,
> retransmission, dissemination or other use of, or taking of any action in
> reliance
> upon this information, by persons or entities other than the intended
> recipient is
> prohibited.
>
> If you have received this in error, please contact the sender and delete
> this e-mail
> and associated material from any computer.
>
> The intended recipient of this e-mail may only use, reproduce, disclose or
> distribute
> the information contained in this e-mail and any attached files, with the
> permission
> of the sender.
>
> This message has been scanned for viruses.
>
> _______________________________________________________________________________________
>
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
>



-- 
George Henke
(C) 845 401 5614

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to