Shane,
I guess I'm misuderstood.
I don't discuss how many links should be used (IMHO two is OK), I'm
talking about single link definition: doeas it consume one or two chpid
numbers. Let me explain it again:
Classic connection:
MVS -CHP10 ---- CHP11-CF
CHP 10 is ICS, CHP 11 is ICR.
Now peer mode link, version A:
MVS -CHP11- CF
Is the above possible ?
Or, the only way is version B:
MVS -CHP10 ---- CHP11-CF
which is the same as classic, with the exception both CHPs are defined
as ICP.
Regards
--
Radoslaw Skorupka
Lodz, Poland
ibm-main wrote:
"peer mode" links could use a single link, although I always define
multiples.
No extra cost for the emulated ones within a (single) CEC.
Shane ...
From: "R.S."
"Classic" link requires two chpids, one for ICS, the second for ICR.
Is it possible to establish MVS-CF link using *one* ICP emulated chpid ?
----------------------------------------------------------------------