<[EMAIL PROTECTED]> wrote in message
news:<[EMAIL PROTECTED]>...
> But I tried this.  Since my data set names will be the same in all LPARs,
> and the IDCAMS RM says, "Allows [not Requires] ... using system symbols,"
> I saw no need to incorporate a variable part,
>
> I get:
>
>     IDCAMS  SYSTEM SERVICES    TIME: 09:19:13      11/20/05     PAGE
1
>
>         DEFINE ALIAS( NAME( SPPG.TEST.ALIAS2 ) -
>             SYMBOLICRELATE( SPPG.TEST.ALIAS0 ) )
>     IDC3014I CATALOG ERROR
>     IDC3009I ** VSAM CATALOG RETURN CODE IS 64 - REASON CODE IS
IGG0CLEK-8
>     IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12
>
>         DEFINE ALIAS( NAME( SPPG.TEST.ALIAS1 ) -
>                     RELATE( SPPG.TEST.ALIAS0 ) )
>     IDC0001I FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS 0
>
>     IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 12
>

> -- gil

No, it's because you didn't specify any symbolics in the SYMBOLICRELATE
keyword.

Thanks,
Mark Thomen
Catalog/IDCAMS/VSAM Development

----------------------------------------------------------------------