Point-and-shoot fields do not have to be in a scrollable area.

Regards,
John K


                                                                                
                                       
  From:       Micheal Butz <michealb...@optonline.net>                          
                                       
                                                                                
                                       
  To:         IBM-MAIN@bama.ua.edu                                              
                                       
                                                                                
                                       
  Date:       02/08/2011 09:39 AM                                               
                                       
                                                                                
                                       
  Subject:    Re: Components for ISPF point & shoot                             
                                       
                                                                                
                                       





Sorry in )PNTS.section. I had it as VALUE


Just looking at the examples in the manuals does point and shoot have
to be in a )AREA section



Sent from my iPhone

On Feb 8, 2011, at 10:25 AM, Dave Salt <ds...@hotmail.com> wrote:

> Instead of this:
>
> FIELD(ZPS00001) VAR(tstfld) VALUE('test')
>
> Try this:
>
> FIELD(ZPS00001) VAR(tstfld) VAL('test')
>
> Hope that helps,
>
> Dave Salt
>
> SimpList(tm) - try it; you'll get it!
>
> http://www.mackinney.com/products/program-development/simplist.html
>
>> Date: Tue, 8 Feb 2011 10:05:35 -0500
>> From: michealb...@optonline.net
>> Subject: Components for ISPF point & shoot
>> To: IBM-MAIN@bama.ua.edu
>>
>> Maybe I am missing something but the two components I need to setup a
>> point and shoot field on a ISPF panel are
>>
>> Attr field in the ) Attr section on the panel
>>
>> E.G. @ TYPE(PS)
>>
>> Then after the panel definition
>>
>>
>> )PNTS
>>
>>  FIELD(ZPS00001) VAR(tstfld) VALUE('test')
>>
>> )
>>
>> In )BODY. Section
>>
>>
>> I have the VAR. Value defined
>>
>> In the following way  + TEST FIELD =>  @tstfld
>>
>> I must be missing something because I am getting a panel error
>>
>> Thankx
>>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to lists...@bama.ua.edu with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html