Silly mistake on my part. When I copied the ISRT to make it a PURG, I forgot to remove the third parameter. Now it works fine.
On Tue, 22 Mar 2011 11:58:32 -0300 Paulo Roberto Leonardo Pereira <[email protected]> wrote: :>A2: :>Explanation: The program issued a CHNG call against an invalid PCB. The PCB :>was invalid for one of these reasons: :>- It was not an alternate PCB. :>- It was an alternate PCB, but it was not modifiable. :>- It was being used to process a message and had not completed processing :>it. :> :>Programmer Response: Check the PCB that was used by the CHNGcall and :>determine which PCB should have been used for the call. :> :> :> :> :>2011/3/22 Binyamin Dissen <[email protected]> :> :>> I have a PSB with a modifiable PCB. I issue a CHNG, ISRT and PURG for the :>> first transaction. All is fine. :>> :>> I then try to issue another CHNG to a different transaction and I get an :>> A2. :>> :>> What am I missing? -- Binyamin Dissen <[email protected]> http://www.dissensoftware.com Director, Dissen Software, Bar & Grill - Israel Should you use the mailblocks package and expect a response from me, you should preauthorize the dissensoftware.com domain. I very rarely bother responding to challenge/response systems, especially those from irresponsible companies. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html