Hi all
We want to assign a DC (DCPS) to HLQ(ABSP.CEB.**) and DSORG=PS
Below is the ACS rounting:
------------------------------------------------------------------------
PROC DATACLAS
FILTLIST ABSPPS INCLUDE(ABSP.CEB.**)
SELECT
WHEN ((&DSORG = 'PS') && (&DSN = &ABSPPS)) SET &DATACLAS = 'DCPS'
WHEN (&DATACLAS NE '') SET &DATACLAS = &DATACLAS
OTHERWISE SET &DATACLAS = 'DCSTD'
END
END
------------------------------------------------------------------------
Then the ACS and DC were activate.
If we used ispf p.3.2 to allocate a DATASET "ABAS.CEB.TEST" and Directory=0,
DC of the dataset was assigned as DCPS.
I deleted the dataset "ABAS.CEB.TEST';
Then the following jcl was submitted to allocated the same dataset.
//ALOCHSKP EXEC PGM=IEFBR14
//MESSAGE DD DSN=ABSP.CEB.TEST,DISP=(NEW,CATLG,DELETE),
// UNIT=3390,SPACE=(4096,(10,10))
This time DC of the dataset was assign as DCSTD
What's wrong ?
Any suggestion are appreciated !
Jason Cai
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html