On Mon, 25 Apr 2011 14:44:25 -0400, Shaffer, Terri E
<[email protected]> wrote:

>You can run a batchjob to pull the information also; I test out my IEFUSI,
by changing MEMLIMIT, REGION...etc. This will dump all region values/limits.
>
>//JS10    EXEC PGM=IKJEFT01,
>//             DYNAMNBR=50
>//SYSTSPRT  DD SYSOUT=*
>//SYSPRINT  DD SYSOUT=*
>//SYSTSIN   DD *
> TEST 'SYS1.LINKLIB(IEFBR14)'
> EQUATE ASCB 0.+224%
> EQUATE RSME ASCB+16C?
> L RSME LEN(230) XC
> EQUATE MLIM RSME+98
> EQUATE MSRC RSME+B8
> EQUATE LDA ASCB+30?
> L LDA LEN(230) XC
> L MLIM LEN(8) XC
> L MSRC LEN(2) XC
>/*
>

TEST?  What's that?   :-)

A lot of shops I've been at actually prevent people from using TEST. 

--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS       