IBM Mainframe Discussion List <IBM-MAIN@BAMA.UA.EDU> wrote on 12/06/2005 
01:37:25 PM:

> Hello: IBM APAR OW40658 details how to determine if a S822 abend is due
> to outstanding captured UCB's.
> 
> They provide the IPCS command 'IOSK CAPTURE' which will provide the
> 'CAPE' address.  They further state to look at the 'NOCJECNT' field of 
the
> 'CAPE' to determine if there are outstanding lasting captures.  However,
> they do not state what offset into the 'CAPE' this 'NOCJECNT' field
> is.  Since there is not a publicly available DSECT for this 'CAPE'
> data area, does anyone know what offset into the 'CAPE' this
> 'NOCJECNT' field is?

  X'14', assuming you are considering the 'CAPE' eycatcher
to be offset X'0'. 

Jim Mulder   z/OS System Test   IBM Corp.  Poughkeepsie,  NY

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to