On Tue, 7 Jun 2011 22:48:10 -0500, Greg Peck wrote:
>
>Is your SYSLMOD a PDSE ? (it probably needs to be)
>
Thanks.  In fact, in my case that was the proper resolution.

However, in the alternative situation, where the programmer has
inadvertently introduced a long name in one of numerous CSECTs
in a load module intended for a PDS, the message is woefully
inadequate for diagnostic purposes.  Simply, it should cite the
offending name.

The problem arose not during an SMP/E APPLY, but in an attempt
to generate relative files for an SMP/E package.

-- gil

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html