> USING CSECTNAME,R15 Or more correctly
USING ENTRYPOINTNAME,R15 CSECTs may have eyecatchers (or anything else the coder wants) before the entry point and/or multiple entry points. Charles -----Original Message----- From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On Behalf Of Gerhard Adam Sent: Saturday, December 10, 2005 4:36 PM To: [email protected] Subject: Re: LOAD MULTIPLE (LM) question Actually you could also simply re-establish addressability, (although it's not as elegant) by simply issuing a DROP R9 and then a USING CSECTNAME,R15 after the LM instruction. At that point you would have program addressability and could restore from the designated work area. It doesn't matter that R15 will be modified since the only remaining instruction doesn't require addressability. ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html