The thing i do in this case is renaming the SMPPTS files in such a way the one 
with the most free space became SMPPTS1, next one SMPPTS2 and so on. This will 
avoid E37 and unneeded compresses. SMP does not have any trouble with that.  

Regards Ron 
  ----- Original Message ----- 
  From: Howard Rifkind 
  Newsgroups: bit.listserv.ibm-main
  Sent: Thursday, December 15, 2005 10:06 PM
  Subject: Extent SMPPTS Question


  I'm getting E37's when receiving new sysmods from tape into the system.
     
    I added 2 DDDF's to the SMP structure and allocated the datasets on two 
seperate volumes and when I run the job to recieve the sysmods I'm still 
running out of room.
     
    What am I missing?
     
    How do concatnate the two new datasets on new volumes to the SMPPTS file.
     
    Hope I got this right.  Thanks.


  ---------------------------------