I'm not going to RUN these "delinked" modules! They are just for the BIND MANAGER to read and search for whatever (contoken I assume). (They are just "indata" here.)
Regards, Thomas Berg _________________________________________ Thomas Berg Specialist A M SWEDBANK > -----Ursprungligt meddelande----- > Från: IBM Mainframe Discussion List [mailto:[email protected]] För John > P Kalinich > Skickat: den 9 september 2011 14:08 > Till: [email protected] > Ämne: Re: SV: SV: SV: How to "splitting" loadmudules > > I am assuming the calling sequence in A is: > > L R15,=V(X) > BASR R14,R15 > > How are you going to change that code in A? > > Regards, > John K > > > > > > > SV: SV: SV: How to "splitting" loadmudules > > Thomas Berg > to: > IBM-MAIN > 09/09/2011 07:00 AM > > > Sent by: > IBM Mainframe Discussion List <[email protected]> > Please respond to IBM Mainframe Discussion List > > > > > > > There is no missing CSECTs ? > (I'm using NOCALL, in the example by Tom below there would be > "bare"/NOCALL modules: X, Y, Z and N. And maybe Y(2) and Z(2) which would > be placed on another loadlib.) > > > Regards, > Thomas Berg > _________________________________________ > Thomas Berg Specialist A M SWEDBANK > > > > > > > -----Ursprungligt meddelande----- > > Från: IBM Mainframe Discussion List [mailto:[email protected]] För > John > > P Kalinich > > Skickat: den 9 september 2011 13:48 > > Till: [email protected] > > Ämne: Re: SV: SV: How to "splitting" loadmudules > > > > Thomas, > > > > How is the relink going to resolve the missing CSECT's? > > > > Regards, > > John K > > > > > > > > > > > > > > SV: SV: How to "splitting" loadmudules > > > > Thomas Berg > > to: > > IBM-MAIN > > 09/09/2011 06:44 AM > > > > > > Sent by: > > IBM Mainframe Discussion List <[email protected]> > > Please respond to IBM Mainframe Discussion List > > > > > > > > > > > > > > > -----Ursprungligt meddelande----- > > > Från: IBM Mainframe Discussion List [mailto:[email protected]] För > > Tom > > > Marchant > > > Skickat: den 9 september 2011 13:30 > > > Till: [email protected] > > > Ämne: Re: SV: How to "splitting" loadmudules > > > > > > On Fri, 9 Sep 2011 12:11:37 +0200, Thomas Berg wrote: > > > > > > >There's a LOT of duplicates of submodules. And it reads all CSECTs. > > > > > > So you have load module A containing CSECTS X, Y and Z. > > > You also have load module B containing CSECTS N, Y and Z. > > > > > > And you are certain that CSECTS Y and Z in load modules A and B > > > perform identical functions? > > > > I'm also checking linkdates and sizes. > > > > > > > > Regards, > > Thomas Berg > > _________________________________________ > > Thomas Berg Specialist A M SWEDBANK > > > > ---------------------------------------------------------------------- > > For IBM-MAIN subscribe / signoff / archive access instructions, > > send email to [email protected] with the message: GET IBM-MAIN INFO > > Search the archives at http://bama.ua.edu/archives/ibm-main.html > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html > > ---------------------------------------------------------------------- > For IBM-MAIN subscribe / signoff / archive access instructions, > send email to [email protected] with the message: GET IBM-MAIN INFO > Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [email protected] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html

