I'm not going to RUN these "delinked" modules! 
They are just for the BIND MANAGER to read and search for whatever (contoken I 
assume). 
(They are just "indata" here.)


 
Regards, 
Thomas Berg 
_________________________________________ 
Thomas Berg   Specialist   A M   SWEDBANK 

 

> -----Ursprungligt meddelande-----
> Från: IBM Mainframe Discussion List [mailto:[email protected]] För John
> P Kalinich
> Skickat: den 9 september 2011 14:08
> Till: [email protected]
> Ämne: Re: SV: SV: SV: How to "splitting" loadmudules
> 
> I am assuming the calling sequence in A is:
> 
> L    R15,=V(X)
> BASR R14,R15
> 
> How are you going to change that code in A?
> 
> Regards,
> John K
> 
> 
> 
> 
> 
> 
> SV: SV: SV: How to "splitting" loadmudules
> 
> Thomas Berg
> to:
> IBM-MAIN
> 09/09/2011 07:00 AM
> 
> 
> Sent by:
> IBM Mainframe Discussion List <[email protected]>
> Please respond to IBM Mainframe Discussion List
> 
> 
> 
> 
> 
> 
> There is no missing CSECTs ?
> (I'm using NOCALL, in the example by Tom below there would be
> "bare"/NOCALL modules: X, Y, Z and N.  And maybe Y(2) and Z(2) which would
> be placed on another loadlib.)
> 
> 
> Regards,
> Thomas Berg
> _________________________________________
> Thomas Berg   Specialist   A M   SWEDBANK
> 
> 
> 
> 
> 
> > -----Ursprungligt meddelande-----
> > Från: IBM Mainframe Discussion List [mailto:[email protected]] För
> John
> > P Kalinich
> > Skickat: den 9 september 2011 13:48
> > Till: [email protected]
> > Ämne: Re: SV: SV: How to "splitting" loadmudules
> >
> > Thomas,
> >
> > How is the relink going to resolve the missing CSECT's?
> >
> > Regards,
> > John K
> >
> >
> >
> >
> >
> >
> > SV: SV: How to "splitting" loadmudules
> >
> > Thomas Berg
> > to:
> > IBM-MAIN
> > 09/09/2011 06:44 AM
> >
> >
> > Sent by:
> > IBM Mainframe Discussion List <[email protected]>
> > Please respond to IBM Mainframe Discussion List
> >
> >
> >
> >
> >
> >
> > > -----Ursprungligt meddelande-----
> > > Från: IBM Mainframe Discussion List [mailto:[email protected]] För
> > Tom
> > > Marchant
> > > Skickat: den 9 september 2011 13:30
> > > Till: [email protected]
> > > Ämne: Re: SV: How to "splitting" loadmudules
> > >
> > > On Fri, 9 Sep 2011 12:11:37 +0200, Thomas Berg wrote:
> > >
> > > >There's a LOT of duplicates of submodules. And it reads all CSECTs.
> > >
> > > So you have load module A containing CSECTS X, Y and Z.
> > > You also have load module B containing CSECTS N, Y and Z.
> > >
> > > And you are certain that CSECTS Y and Z in load modules A and B
> > > perform identical functions?
> >
> > I'm also checking linkdates and sizes.
> >
> >
> >
> > Regards,
> > Thomas Berg
> > _________________________________________
> > Thomas Berg   Specialist   A M   SWEDBANK
> >
> > ----------------------------------------------------------------------
> > For IBM-MAIN subscribe / signoff / archive access instructions,
> > send email to [email protected] with the message: GET IBM-MAIN INFO
> > Search the archives at http://bama.ua.edu/archives/ibm-main.html
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html
> 
> ----------------------------------------------------------------------
> For IBM-MAIN subscribe / signoff / archive access instructions,
> send email to [email protected] with the message: GET IBM-MAIN INFO
> Search the archives at http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to