> Without seeing more information, GIM24001E makes me think ASMPRINT. Do
you
> have such a DD or DDDEF in place?
>
> Here's some quick information:
>
>
http://publib.boulder.ibm.com/infocenter/zos/v1r11/index.jsp?topic=/com.ibm.
zos.r11.
> e0zm100/smpejes.htm
>
> Regards,
>
> Kevin
>
> -----Original Message-----
> From: IBM Mainframe Discussion List [mailto:[email protected]] On
Behalf Of
> saurabh khandelwal
> Sent: Thursday, December 29, 2011 9:15 PM
> To: [email protected]
> Subject: RSU Apply Error in PTF
>
> >
> > Hello,
> > Currently I am applying RSU1110 on z/Os 1.11 system.
> > I run apply job after apply check job run successfully with RC 00.
> >
> > But in apply job I received RC 08 for some of the PTF. When I looked
> > at output , I found most of the PTF failed because of UA59434 PTF. In
> > more detail I found below error in my job.
> >
> > CAUSER FMID MESSAGE ID PAGE ERROR DESCRIPTION AND POSSIBLE
> CAUSES
> >
> > UA59434 HJE7760 GIM24001E 8 ASSEMBLER PROCESSING FAILED FOR
> > MODULE ISFDA IN THE SISFSRC1 LIBRARY. THE RETURN
> > CODE WAS 04.
> > --- POSSIBLE CAUSES ---
> > 1. THE ASSEMBLER TEXT WAS IN
ERROR.
> > 2. THE WRONG LEVEL OF MACROS WAS
> > BEING USED.
> > 3. THE WRONG SET OF MACLIBS WAS
> > BEING USED.
> >
> > I am really not getting clue to resolve this issue. I am attaching
> > apply job output. Can you please help me to resolve this issue.
> >
> > Regards
> >
> >
> >
I have looked at his SMP/E report. There are many errors related to this
one PTF
GIM24001E ** ASSEMBLER PROCESSING FOR SYSMOD UA59434 FAILED FOR MODULE ISFDA
IN
THE SISFSRC1 LIBRARY. THE RETURN CODE (04) EXCEEDED THE
ALLOWABLE
VALUE. DATE 11.343 - TIME 09:50:34.
GIM30227E ** APPLY PROCESSING FAILED FOR SYSMOD UA50744 BECAUSE PROCESSING
FAILED FOR SYSMOD UA59434. SYSMOD UA59434 CONTAINS HIGHER
LEVELS OF
COMMON ELEMENTS.
GIM30227E ** APPLY PROCESSING FAILED FOR SYSMOD UA50558 BECAUSE PROCESSING
FAILED FOR SYSMOD UA59434. SYSMOD UA59434 CONTAINS HIGHER
LEVELS OF
COMMON ELEMENTS.
GIM30227E ** APPLY PROCESSING FAILED FOR SYSMOD UA52851 BECAUSE PROCESSING
FAILED FOR SYSMOD UA59434. SYSMOD UA59434 CONTAINS HIGHER
LEVELS OF
COMMON ELEMENTS.
GIM30227E ** APPLY PROCESSING FAILED FOR SYSMOD UA55171 BECAUSE PROCESSING
FAILED FOR SYSMOD UA59434. SYSMOD UA59434 CONTAINS HIGHER
LEVELS OF
COMMON ELEMENTS.
His DDDEF statements show what I would call Production not SMP/E Tlib
datasets. However, I do understand that sometimes shops will clone their
libraries to a new volume then do a UCLIN to their MVST100 zone to point to
those files.
I have asked how maintenance is done at this shop.
SYSLIB SYSLIB
SMPMTS SYSLIB PERM SMPE.BIN1.MVST100.SMPMTS
MACLIB SMP00001 PERM SYS1.MACLIB
MODGEN SMP00002 PERM SYS1.MODGEN
SISTMAC1 SMP00003 PERM SYS1.SISTMAC1
SEPWMAC1 SMP00004 PERM FFST.V120ESA.SEPWMAC1
SICEUSER SMP00005 PERM SYS1.SICEUSER
SISFMAC SMP00006 PERM ISF.SISFMAC
SASMMAC1 SMP00007 PERM ASM.SASMMAC1
SASMSAM1 SMP00008 PERM ASM.SASMSAM1
SCEEMAC SMP00009 PERM CEE.SCEEMAC
SHASMAC SMP00010 PERM SYS1.SHASMAC
SEZACMAC SMP00011 PERM TCPIP.SEZACMAC
SIGYMAC SMP00012 PERM IGY.SIGYMAC
In the assembly section is has NO ASSEMBLY ERRORs, however it is an RC04.
This might be as simple of saying an RC04 in Assembler is okay. I am not
sure. I did not find any ERROR or ASMA messages in the listing from the
assembly of ISFDA.
Thoughts?
Lizette
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN