On Mon, 23 Jan 2012 09:14:52 -0800, Skip Robinson <[email protected]> 
wrote:

>I'm curious. We have not done 'SET CLOCK' for 15 years since we acquired
>sysplex timers and now have STP. Time changes are automatic/programmed. Is
>the reason for using manual processes strictly financial?
>

Unfortunately the sysplex timer only support 1 offset.   While my client's 
biggest
sysplex runs with pacific time, we have other sysplexes running central time
and some monoplex LPARs running Eastern.  

So while we use the sysplex timer in those environments, we run with
STPZONE NO (formerly ETRZONE) in those environments and get the offset 
from TIMEZONE in CLOCKxx.

Regards,

Mark
--
Mark Zelden - Zelden Consulting Services - z/OS, OS/390 and MVS       
mailto:[email protected]                                        
Mark's MVS Utilities: http://www.mzelden.com/mvsutil.html 
Systems Programming expert at http://expertanswercenter.techtarget.com/

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [email protected] with the message: INFO IBM-MAIN