In
<cahtvvrvyzyc8x03mwmsz3vrdojsd1fie0pdotbif7g+nuus...@mail.gmail.com>,
on 04/03/2012
at 10:54 AM, Jake anderson <[email protected]> said:
>What I deduce from the error message(DD statement)
The error message is not the DD statement, it is "IEH605I INVALID
DEVICE ALLOCATED ON D72D".
>I also see that 890 is properly added in our IODF.
Why would that matter when you are not allocating 890? Why didn't you
check and fix your ACS?
>This really looks strange.
No, it looks like you blew off the explanations you were already
given. The problem is in your ACS.
--
Shmuel (Seymour J.) Metz, SysProg and JOAT
ISO position; see <http://patriot.net/~shmuel/resume/brief.html>
We don't care. We don't have to care, we're Congress.