On Wed, 11 Jan 2006 11:01:59 +0100 Miklos Szigetvari
<[EMAIL PROTECTED]> wrote:

:>Our APF auth application calls a C++ XPLINK module , and during the 
:>initialisation we got  an
:>S0C4 in CELVH003 offset +4.
:>The SYSMDUMP says "loading task not secure"
:>The module is in SP251 KEY1 storage and the caller is in KEY8.
:>Why the module in SP251 KEY1 ?

Would occur if the loading TCB was in key one and the modules is not
reentrant.

--
Binyamin Dissen <[EMAIL PROTECTED]>
http://www.dissensoftware.com

Director, Dissen Software, Bar & Grill - Israel


Should you use the mailblocks package and expect a response from me,
you should preauthorize the dissensoftware.com domain.

I very rarely bother responding to challenge/response systems,
especially those from irresponsible companies.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to