We are using PPRC Cestpair to duplex our DB2 farm for DR Backups. Have done it for years with no problem.
Now I'm getting the following: CESTPAIR DEVN(X'1320') PRIM(X'1300',45342,X'20',X'03') SEC(X'1300',45342,X'21',X'03') MODE(COPY) PACE(100) COMMAND CONFLICTS WITH ESTABLISHED PPRC DEVICE STATE CESTPAIR COMMAND UNSUCCESSFUL FOR DEVICE 1320. COMPLETION CODE: 08 A similiar command earlier in the sequence works with no problem: CESTPAIR DEVN(X'132A') PRIM(X'1300',45342,X'2A',X'03') SEC(X'1300',45342,X'28',X'03') MODE(COPY) PACE(100) CESTPAIR COMMAND COMPLETED FOR DEVICE 132A. COMPLETION CODE: 00 READY The secondary volume has been varied offline to all other LPARs and has been detached from Z/VM. The hardware is an HDS 9990V. Is it possible I've hit a ceiling for the amount of PPRC Duplex volumes? We are currently duplexing 208 volumes. Any thoughts appreciated. Thank You, Dave O'Brien NIH Contractor ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to lists...@bama.ua.edu with the message: INFO IBM-MAIN