I ran a LISTCAT ALL for the dataset and the SMS DATA was missing.  I did
CONVERTV SMS DYNAM(USMS01) REDETERMINE and now it can be dumped.

Thanks for all the replies,
   Craig

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Matthew Stitt
Sent: Wednesday, January 18, 2006 2:20 PM
To: [email protected]
Subject: Re: ADR793E - VTOC and VVDS do not match?

I believe he has managed to place a non-SMS dataset on an SMS managed
volume.  I wonder if the ADRDSSU CONVERTV command would fix him up.

Since it is a SMP/E SMPLTS file, he would be safe in deleting it and
allocate a new one.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html