You are looking at a list which states that SYSMOD HCI6400) has APAR PK03409
open against it.  The PTF which resolves this APAR is UK04749.

On Tue, 24 Jan 2006 14:22:49 -0600, Chase, John <[EMAIL PROTECTED]> wrote:

>> -----Original Message-----
>> From: IBM Mainframe Discussion List On Behalf Of Thomas Lawrence
>>
>> I've already received the tape not realizing that if I added
>> HOLDDATA to the receive I would have received a separate file
>> containing holddata. I tried a listing using GIMSMP and got
>> short lines wherein the holddata mostly looks like this:
>>
>> HOLDERROR       = AK03409   ++HOLD(HCI6400) FMID(HCI6400)
>> REASON(AK03409) ERROR DATE(05176)
>> COMMENT(SMRTDATA(FIX(UK04749) SYMP(IPL)
>> CHGDT(050625))) CLASS(HIPER).
>>
>> and I don't really understand it.
>
>You can do a RECEIVE HOLDDATA from that same tape by defining it to DDName
>SMPHOLD, after which you can run a REPORT ERRSYSMODS to "decipher" the error
>holddata.  (Both are SMP/E jobs.)
>
>    -jc-
>

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html