post the jcl 

-----Original Message-----
From: IBM Mainframe Discussion List
[mailto:[EMAIL PROTECTED] On Behalf Of Francis
ANDRE
Sent: Monday, January 30, 2006 3:44 AM
To: [email protected]
Subject: Re: Newbie: Concatenate sysprint from
precompiler, compiler and linkeditor in a single PDSE
member

Hello

While I am trying the sort option, I got an error when
it open the SORTIN as

ICZ063A  OPEN ERROR SORTIN


while SORTIN is defined as in your mail

//SORTIN  DD DSN=&&PRINT1,DISP=(OLD,DELETE)
                  DD DSN=&&PRINT2,DISP=(OLD,DELETE)


Is there any way to understand why the OPEN fails??

Regs

FA
----- Original Message -----
From: "tony babonas" <[EMAIL PROTECTED]>
Newsgroups: bit.listserv.ibm-main
To: <[email protected]>
Sent: Wednesday, January 25, 2006 12:59 AM
Subject: Re: Newbie: Concatenate sysprint from
precompiler, compiler and linkeditor in a single PDSE
member


> easy, allocate a sysprint dataset for each step,
writing output as 
> dsn=&&sysprin1, &&sysprin2,
> &&sysprin3 respectively. then add a step:
>
> // set member=anyname
>
> //step2  exec pgm=sort
> //sortin dd dsn=&&sysprin1,disp=old
>            dd dsn=&&sysprin2,disp=old
>            dd dsn=&&sysprin3,disp=old
> //sortout dd
> dsn=your.existing.pdse.of.lrecl133(&member),disp=shr
> //sysin dd *
>  sort fields=copy

-------------------------------------------------------
---------------
For IBM-MAIN subscribe / signoff / archive access
instructions, send email to [EMAIL PROTECTED] with
the message: GET IBM-MAIN INFO Search the archives at
http://bama.ua.edu/archives/ibm-main.html

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html

Reply via email to