The only COBOL compiler we have is: PP 5655-G53 IBM Enterprise COBOL for
z/OS  3.4.0.

-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Bill Klein
Sent: Wednesday, February 01, 2006 3:57 AM
To: [email protected]
Subject: What is ILBOSPI0 ?

The information that I have from a "usually reliable source" is that if

A) the program is not compiled with OS/VS COBOL
     OR
B) if compiled with OS/VS COBOL but without  STATE, COUNT, SYMDMP

then such a call is a "NO-OP" and can safely be removed.

If you still have an OS/VS COBOL compiled program *and* use the FLOW=
run-time option (still supported with LE - but ONLY for OS/VS COBOL
programs), then your existing CALL statement *might* actually be doing
something.

----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html