John Chase wrote,

>If you specify a value other than TIME=NOLIMIT or TIME=1440, SMF uses its
>current job wait time limit."

This says that there is no wait or CPU time limit if TIME=NOLIMIT or 1440.

>That last sentence is where the confusion arose, because we had always
>believed that the TIME specified in JES2 JOBCLASS and on the JOB or EXEC
>statements referred to CPU time, and JWT in SMFPRM referred to wallclock
>time.  Apparently that is not true?

You are correct.  JWT is the only real time measurement.

Regards,
John Kalinich