John Chase wrote, >If you specify a value other than TIME=NOLIMIT or TIME=1440, SMF uses its >current job wait time limit."
This says that there is no wait or CPU time limit if TIME=NOLIMIT or 1440. >That last sentence is where the confusion arose, because we had always >believed that the TIME specified in JES2 JOBCLASS and on the JOB or EXEC >statements referred to CPU time, and JWT in SMFPRM referred to wallclock >time. Apparently that is not true? You are correct. JWT is the only real time measurement. Regards, John Kalinich Computer Sciences Corp ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html