Hi, Bob. Does APAR OA09652 describe your environment?
Regards, Peggy On Tue, 28 Feb 2006 09:36:40 -0600, Bob Henry <[EMAIL PROTECTED]> wrote: >I successfully used a 'D A,L' as a batch JCL command which tells me that >the MVS side is ok, right? I actually have multiple 'F CICSxx,'CEMT INQ >TAS'' commands in a job which get directed to multiple CICS regions (jobs, >not stc). If the CICS region is not active, I get an IEE341I "NOT ACTIVE" >message (expected) and I don't get the IEE345I message. If the target CICS >region is active, I get the IEE345I. That tells me that there is something >wrong in the CICS definitions. These same definitions worked in OS/390 >2.10 with CICS/TS 1.3. I have my real console (CONS700) set up as a CICS >console and that successfully accepts modify commands. I also >have "INTERNAL" set up for JCL statements and have added "INSTREAM" as >another console. When I run the batch job, the MVS syslog shows the modify >command coming from "INSTREAM" but even with that defined in CICS, I still >get the IEE345I error. > >Signed ... "Frustrated" > >---------------------------------------------------------------------- >For IBM-MAIN subscribe / signoff / archive access instructions, >send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO >Search the archives at http://bama.ua.edu/archives/ibm-main.html ---------------------------------------------------------------------- For IBM-MAIN subscribe / signoff / archive access instructions, send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO Search the archives at http://bama.ua.edu/archives/ibm-main.html