Hello Ed,

as you said, with some HCD work you can get the CTC shared in an LPAR
environment.

The Control Units have to be defined with CUADD=target lpar number.
And it is good to define the CTC devices with explicit partition lists, so
that a target lpar device is not accessible on that lpar.

By defining the CNC chpid as dedicated you have removed the CUADD
requirement at the cost of not sharing the channel if you add nore LPARs to
that processor.

I am glad that you got a solution that works for you.

Regards
Bruce Hewson

----------------------------------------------------------------------