Ron,
Well it is, i think.. (its been a long day!).. I suppose what i was
trying to get at is that specifying CNTLUNUIT=3990 vs 2105 doesnt do
anything different (apart from HCD only allows D/t 3390A/B for 2105..)
All other control unit function/feature is queried during IPL (RDC and
other subsystem CCWs etc) so even if I have defined 3990 in IOCDS and
the interface is configured as 2105, it should see 2105 function? Is
this Transparancy Mode
Cheers
Roy
Ron and Jenny Hawkins wrote:
Roy,
I meant using Transparency mode by specifying CNTLUNIT=3990, even though the
underlying hardware is emulating a 2105 controller. That's what I thought
you meant.
Ron
-----Original Message-----
From: IBM Mainframe Discussion List [mailto:[EMAIL PROTECTED] On
Behalf Of Roy Hewitt
Sent: Tuesday, 4 April 2006 9:53 PM
To: IBM-MAIN@BAMA.UA.EDU
Subject: Re: 2105 Question
Ron,
When you say 'genned as 3990' I presume you mean how the USP interface
emulation has been defined.
Roy
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html
----------------------------------------------------------------------
For IBM-MAIN subscribe / signoff / archive access instructions,
send email to [EMAIL PROTECTED] with the message: GET IBM-MAIN INFO
Search the archives at http://bama.ua.edu/archives/ibm-main.html