Your job requests tape 000000.  You mounted tape 01862A.  It looks like your 
tape management software (CA-1?) recognized the "mismount" and dropped the tape.
   
  The JCL looks like it is asking for BLP but the mount message specifies SL.  
On my system, a BLP mount does not have the SL following the volser.
   
  On the other hand you showed the DD statement for SYSUT1 but the mount 
message seems to specify a DD name of ANYTAPE.

Dean Montevago <[EMAIL PROTECTED]> wrote:
  Hi,

I'm having trouble running the TAPEMAP program. I'm using the following
JCL:

//SYSUT1 DD UNIT=T3590,VOL=SER=000000, 
// DSN=ANYTAPE, 
// DISP=SHR,LABEL=(,BLP,EXPDT=98000)

I'm trying to do a map of an IBM PTF tape. The tape gets kicked down
with:

TMS014 IEC502E R 0A03,O1862A,SL,TCSIDFMQ,TESTA 
IEC502E R 0A03,O1862A,SL,TCSIDFMQ,TESTA 
*TMS008 IEC501A M 0A03,000000,SL,,TCSIDFMQ,TESTA,ANYTAPE 

Can someone tell me what I am doing wrong ?

                
---------------------------------